| Sign In | Join Free | My autochinanet.com |
|
Brand Name : JSHQ
Model Number : HQ3051/1151/335
Certification : CE
Used to measure the level, density, and pressure of liquids, gases, or vapors, and then convert them into a 4-20mA DC signal output. The intelligent type can communicate with a HART handheld communicator for setting, monitoring, or forming a field monitoring system with a host computer. The HQ-1151/3051/3851/3351DP field-adjustable intelligent differential pressure transmitter is a new product developed by our company according to field requirements. It can be operated independently of a handheld communicator, with zeroing and configuration performed via buttons.

Details:
Performance Specifications
(Reference conditions: No migration, silicone oil port filled, 316L diaphragm)
★Output Signal: 4~20mA DC/RS485 digital communication
4~20mA DC/HART protocol digital communication (optional)
★Transmission Method: Two-wire system.
★Accuracy
Accuracy: ±0.1%, ±0.2%, ±0.5% (Intelligent type)
★Stability: For DP range codes 3, 4, and 5, +0.2% of the highest range; for other range codes, ±0.25% of the highest range.
★Humidity: 0~100% relative humidity.
★Start-up Time: Maximum 2 seconds at minimum damping.
★Volume Absorption: Less than 0.16 cm².
★Damping: Electrical damping is 0~32 seconds. Additionally, the sensing element has a constant damping time of 0.2 seconds (0.4 seconds for range 3).
★Static Pressure Influence (DP Transmitter)
Zero-point Error: +0.25% of the highest range for 14 MPa; +0.5% of the highest range for range code 3. This can be corrected through zero-point adjustment.
Range error: Correctable to +0.25% of the input reading per 6 MPa, or +0.5% for range designation 3. This error can be eliminated by adjustment before installation.
★ Static pressure effect (HP transmitter)
Zero point error: ±1.0% for the highest range at 32 MPa. Correctable by zero point adjustment.
★ Temperature effect
Zero point error at the highest range: +0.5% of the range per 56°C. Total effect including range and zero point error: ±1.0% of the range per 56°C. The effect is doubled for range designation 3.
Zero point error at the lowest range: ±3% of the range per 56°C. Total effect including range and zero point error: ±3.5% of the range per 56°C. The effect is doubled for range designation 3.
★ Vibration effect: +0.05% per g in any direction for frequencies from 0 to 200 Hz, upper limit. ★Power Supply Influence: Less than 0.005% /V of the calibrated range.
★Installation Position Influence: Zero drift not greater than (0.25kPa), this error can be eliminated through calibration and has no impact on the range.
★Electromagnetic Interference/RF Interference Influence: Tested according to SAMA PMC33.1, from 20 ~ 000MHz, field strength can be up to 30V/m. Structural Specifications
Materials in Contact with Media:
Isolation Diaphragm: 316L stainless steel, Hastelloy C-276, Monel alloy, or tantalum. (Optional)
Exhaust/Drain Valve: 316 stainless steel, Hastelloy, or Monel alloy.
Process Flanges and Connectors: 316 stainless steel, Hastelloy, or Monel alloy.
O-rings in Contact with Media: Fluororubber, Nitrile rubber. (Optional)
→ Filling fluid: Silicone oil
→ Bolts: Cadmium-plated carbon steel
→ Electronic circuit housing: Low-copper aluminum
→ O-rings: Nitrile rubber, fluororubber (optional)
→ Paint: Polyurethane.
Process connections: For transmitters with range codes 3, 4, and 5, the center-to-center distance between the two flanges is 54 mm, with NPT1/4-18 on the holes; for transmitters with codes 6 and 7, it is 56 mm and NPT1/4-18; for transmitters with code 2.8, it is 57.2 mm and NPTI/4-18. For transmitters with range codes 3, 4, and 5, the pressure taps on the two connectors are NPT1/2-14, and the flange connectors can be flipped to provide center distances of 50.8 mm, 54 mm, or 57.2 mm respectively.
Electrical connections: Equipped with field-connected online test terminals.
Weight: Excluding optional parts, AP, DP, GP, and HP models weigh 2.8 kg. Usage Conditions
Overall protection performance meets: IP67 (related parameters)
★Power Supply Voltage:
16V ~ 45V DC Intrinsically safe explosion-proof products must be powered by a corresponding safety barrier (standard is 24V DC)
★Product Operating Environment
Operating Temperature: -25℃ ~ +85℃
Storage Temperature: -40℃ ~ +104℃
Humidity: 0 ~ 90%
Explosion-proof Product Operating Environment Conditions:
Temperature: -20℃ ~ +40℃
Relative Humidity: 5% ~ 95%
Atmospheric Pressure: 86 ~ 106kPa
Intrinsically safe product external safety barrier parameters:
U0≤28V DC 10≤30mA P0≤0.84W
Product Selection
| HQ3051/1151/3351 | Differential Pressure Transmitter | |||||||||||
| Product Type | AP- | Pressure Transmitter | ||||||||||
| DR- | Differential pressure transmitter | |||||||||||
| DP- | Differential pressure transmitter | |||||||||||
| Specifications range | 1 | 0-0.6~6KPa | ||||||||||
| 2 | 0-4~40KPa | |||||||||||
| 3 | 0-40~200KPa | |||||||||||
| 4 | 0-160~700KPa | |||||||||||
| 5 | 0-20-200KPa | |||||||||||
| 6 | 0-1.6~7.0MPa | |||||||||||
| 7 | 0-4~20MPa | |||||||||||
| 8 | 0-4.0~40MPa | |||||||||||
| 9 | 0-10-60MPa | |||||||||||
| 10 | -0.1-0MPa | |||||||||||
| Output | E1 | Two-line system(4~20)mA | ||||||||||
| E2 | HART Protocol output | |||||||||||
| E3 | RS485 Protocol | |||||||||||
| E5 | | |||||||||||
| Display method | M1 | 0~100% Linearity Indicator | ||||||||||
| M2 | LED LCD digital display | |||||||||||
| M3 | LCD LCD digital display | |||||||||||
| Flange joint material | B | Stainless Steel 316 | ||||||||||
| HC | Hastelloy C | |||||||||||
| M | Monel | |||||||||||
| Material of exhaust/liquid valve | B | Stainless Steel 316 | ||||||||||
| HC | Hastelloy C | |||||||||||
| M | Monel | |||||||||||
| Isolation diaphragm | B | Stainless Steel 316 | ||||||||||
| HC | Hastelloy C | |||||||||||
| D | Tantalum | |||||||||||
| M | Monel | |||||||||||
| Filling liquid | G | Silicone oil | ||||||||||
| Electrical interface | 1 | M20*1.5(Standard) | ||||||||||
| 2 | G1/2 | |||||||||||
| Power supply method | AC | 220VAC | ||||||||||
| DC | 24VDC | |||||||||||
| D | 3.6V Battery | |||||||||||
| T | Solar power | |||||||||||
| Explosion-proof | N | No explosion-proof requirements | ||||||||||
| D | Explosion-proof EXd II CT6 | |||||||||||
|
|
Flange High Temperature Flat Membrane Pressure Transmitter Images |